{"product_id":"cra-d-plate-forged-d-ring-anchor-red-powder-coating","title":"CRA D-Plate Forged D-Ring Anchor Red Powder Coating","description":"\u003cstyle\u003e.fpc-sd-pdp{--fpc-navy:#0a1628;--fpc-red:#c8102e;--fpc-ink:#1a1a1a;--fpc-muted:#5a6472;--fpc-line:#e5e7eb;--fpc-bg:#f7f8fa;--fpc-amber:#f59e0b;font-family:'Inter',system-ui,-apple-system,sans-serif;color:var(--fpc-ink);line-height:1.6;max-width:100%;margin:0}.fpc-sd-pdp *{box-sizing:border-box}.fpc-sd-pdp h2,.fpc-sd-pdp h3,.fpc-sd-pdp h4{font-family:'Oswald',sans-serif;font-weight:600;letter-spacing:.01em;color:var(--fpc-navy);margin-top:0}.fpc-sd-pdp h2{font-size:1.75rem;border-left:4px solid var(--fpc-red);padding-left:14px;margin:2.25rem 0 1rem}.fpc-sd-pdp h3{font-size:1.2rem;margin:1.5rem 0 .6rem}.fpc-sd-pdp h4{font-size:1rem;text-transform:uppercase;letter-spacing:.08em;margin:1rem 0 .5rem;color:var(--fpc-navy)}.fpc-sd-pdp p{margin:.6rem 0}.fpc-sd-pdp a{color:var(--fpc-red);text-decoration:none;border-bottom:1px solid rgba(200,16,46,.3)}.fpc-sd-pdp a:hover{border-bottom-color:var(--fpc-red)}.fpc-sd-lede{font-size:1.05rem;color:var(--fpc-ink);padding:1rem 1.25rem;background:var(--fpc-bg);border-left:3px solid var(--fpc-navy);margin:0 0 1.5rem}.fpc-sd-alert{display:flex;gap:.75rem;align-items:flex-start;padding:1rem 1.15rem;background:#fff8e6;border:1px solid #f3d38a;border-left:4px solid var(--fpc-amber);border-radius:4px;margin:1.25rem 0;font-size:.95rem}.fpc-sd-alert strong{color:#7a4f00;display:block;margin-bottom:.2rem;font-family:'Oswald',sans-serif;letter-spacing:.02em;text-transform:uppercase;font-size:.82rem}.fpc-sd-alert-icon{flex:0 0 22px;color:var(--fpc-amber);font-weight:700;font-size:1.1rem;line-height:1.4}.fpc-sd-quick{display:grid;grid-template-columns:repeat(auto-fit,minmax(160px,1fr));gap:.75rem;margin:1.25rem 0 1.75rem}.fpc-sd-quick-item{background:var(--fpc-navy);color:#fff;padding:.9rem 1rem;border-radius:3px;border-top:3px solid var(--fpc-red)}.fpc-sd-quick-label{font-family:'Oswald',sans-serif;text-transform:uppercase;letter-spacing:.1em;font-size:.72rem;opacity:.75;margin-bottom:.2rem}.fpc-sd-quick-value{font-family:'Oswald',sans-serif;font-size:1.05rem;font-weight:500;line-height:1.25}.fpc-sd-features{list-style:none;padding:0;margin:.5rem 0 1.5rem}.fpc-sd-features li{position:relative;padding:.55rem 0 .55rem 28px;border-bottom:1px solid var(--fpc-line);font-size:.98rem}.fpc-sd-features li:last-child{border-bottom:none}.fpc-sd-features li::before{content:\"\";position:absolute;left:4px;top:1.05rem;width:8px;height:8px;background:var(--fpc-red);transform:rotate(45deg)}.fpc-sd-spec-table{width:100%;border-collapse:collapse;margin:.5rem 0 1.5rem;font-size:.95rem}.fpc-sd-spec-table th,.fpc-sd-spec-table td{padding:.7rem .9rem;text-align:left;border-bottom:1px solid var(--fpc-line);vertical-align:top}.fpc-sd-spec-table th{background:var(--fpc-navy);color:#fff;font-family:'Oswald',sans-serif;font-weight:500;letter-spacing:.04em;text-transform:uppercase;font-size:.82rem;width:38%}.fpc-sd-spec-table tr:nth-child(even) td{background:var(--fpc-bg)}.fpc-sd-usecase{display:grid;grid-template-columns:repeat(auto-fit,minmax(230px,1fr));gap:1rem;margin:1rem 0 1.5rem}.fpc-sd-usecase-card{padding:1.1rem 1.2rem;background:#fff;border:1px solid var(--fpc-line);border-top:3px solid var(--fpc-navy);border-radius:3px}.fpc-sd-usecase-card h3{margin:0 0 .4rem;font-size:.95rem;color:var(--fpc-navy);font-family:'Oswald',sans-serif;font-weight:600}.fpc-sd-usecase-card p{font-size:.9rem;margin:0;color:var(--fpc-muted)}.fpc-sd-faq{margin:1rem 0 1.5rem}.fpc-sd-faq details{border-bottom:1px solid var(--fpc-line);padding:.75rem 0}.fpc-sd-faq summary{cursor:pointer;font-family:'Oswald',sans-serif;font-weight:500;color:var(--fpc-navy);font-size:1.02rem;padding-right:1.5rem;position:relative;list-style:none}.fpc-sd-faq summary::-webkit-details-marker{display:none}.fpc-sd-faq summary::after{content:\"+\";position:absolute;right:0;top:-2px;color:var(--fpc-red);font-size:1.4rem;font-weight:300;transition:transform .2s}.fpc-sd-faq details[open] summary::after{content:\"−\"}.fpc-sd-faq details p{margin:.65rem 0 0;color:var(--fpc-ink);font-size:.96rem}.fpc-sd-compat{background:var(--fpc-bg);padding:1.1rem 1.25rem;border-radius:3px;border-left:3px solid var(--fpc-red);margin:1rem 0 1.5rem;font-size:.95rem}.fpc-sd-compat strong{color:var(--fpc-navy)}.fpc-sd-ship{display:flex;gap:.85rem;align-items:center;padding:.9rem 1.15rem;background:var(--fpc-navy);color:#fff;border-radius:3px;margin:1.5rem 0;font-size:.95rem}.fpc-sd-ship-badge{background:var(--fpc-red);color:#fff;font-family:'Oswald',sans-serif;text-transform:uppercase;letter-spacing:.06em;font-size:.72rem;padding:.3rem .55rem;border-radius:2px;flex-shrink:0}@media (max-width:640px){.fpc-sd-pdp h2{font-size:1.45rem}.fpc-sd-spec-table th{width:45%;font-size:.75rem}.fpc-sd-quick{grid-template-columns:repeat(2,1fr)}}\u003c\/style\u003e\u003cdiv class=\"fpc-sd-pdp\"\u003e\n\u003cp class=\"fpc-sd-lede\"\u003eThe Super Anchor CRA — Commercial Roof Anchor — is the engineered tie-off backbone of commercial flat-roof fall protection. Specified by structural engineers and commercial roofing consultants on big-box retail, distribution warehouses, industrial facilities, and institutional buildings across Canada.\u003c\/p\u003e\n\u003cdiv class=\"fpc-sd-alert\"\u003e\n\u003cspan class=\"fpc-sd-alert-icon\"\u003e⚠\u003c\/span\u003e\u003cdiv\u003e\n\u003cstrong\u003eCompliance Notice\u003c\/strong\u003eCommercial roof anchor — engineering review required for permanent installations. A qualified person must review the layout, anchor placement, and fall clearance before installation.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"fpc-sd-quick\"\u003e\n\u003cdiv class=\"fpc-sd-quick-item\"\u003e\n\u003cdiv class=\"fpc-sd-quick-label\"\u003eRiser Height\u003c\/div\u003e\n\u003cdiv class=\"fpc-sd-quick-value\"\u003e(variant)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"fpc-sd-quick-item\"\u003e\n\u003cdiv class=\"fpc-sd-quick-label\"\u003eRated Capacity\u003c\/div\u003e\n\u003cdiv class=\"fpc-sd-quick-value\"\u003e5,000 lb\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"fpc-sd-quick-item\"\u003e\n\u003cdiv class=\"fpc-sd-quick-label\"\u003eConfigurations\u003c\/div\u003e\n\u003cdiv class=\"fpc-sd-quick-value\"\u003e4-Way \/ Pass-Thru \/ W-Loop \/ D-Plate\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"fpc-sd-quick-item\"\u003e\n\u003cdiv class=\"fpc-sd-quick-label\"\u003eFinishes\u003c\/div\u003e\n\u003cdiv class=\"fpc-sd-quick-value\"\u003eHDG \/ 304sst \/ 316sst\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eWhy Commercial Roofers \u0026amp; Engineers Specify the CRA D-Plate Forged D-Ring Anchor Red Powder Coating\u003c\/h2\u003e\n\u003cul class=\"fpc-sd-features\"\u003e\n\u003cli\u003eEngineered specifically for commercial flat-roof and low-slope applications — built into specifier drawing libraries\u003c\/li\u003e\n\u003cli\u003eMultiple top configurations: 4-Way Loop Top (4-direction tie-off), Pass-Thru (HLL cable termination), W-Loop (single direction), D-Plate (D-ring anchor)\u003c\/li\u003e\n\u003cli\u003eAvailable heights match insulation depths: 5″, 8″, 12″, 18″, 24″ risers — anchor top sits at the finished roof surface\u003c\/li\u003e\n\u003cli\u003eHot-dip galvanized (HDG) standard; 304\/316 stainless steel for coastal and corrosive environments\u003c\/li\u003e\n\u003cli\u003eThrough-bolt to structural deck via 16×16″ backer plate (sold separately or with kit)\u003c\/li\u003e\n\u003cli\u003eCompatible with the Super Anchor horizontal lifeline (HLL) system as line terminations and intermediate anchors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCRA D-Plate Forged D-Ring Anchor Red Powder Coating Specifications \u0026amp; Load Ratings\u003c\/h2\u003e\n\u003ctable class=\"fpc-sd-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eSuper Anchor Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Type\u003c\/th\u003e\n\u003ctd\u003eCommercial Roof Anchor (CRA Series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRiser Height\u003c\/th\u003e\n\u003ctd\u003e(variant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTop Configuration\u003c\/th\u003e\n\u003ctd\u003eVariant-specific (4-Way \/ Pass-Thru \/ W-Loop \/ D-Plate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFinishes\u003c\/th\u003e\n\u003ctd\u003eHDG (Hot-Dip Galvanized) \/ 304sst \/ 316sst\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBacker Plate\u003c\/th\u003e\n\u003ctd\u003e16×16×3\/8″ or 16×16×5\/8″ (variant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Capacity\u003c\/th\u003e\n\u003ctd\u003e5,000 lb (single-user)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHLL-Engineered Rating\u003c\/th\u003e\n\u003ctd\u003eHigher capacities available per engineered HLL design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertifications\u003c\/th\u003e\n\u003ctd\u003eOSHA \/ ANSI Z359 \/ CSA Z259 (verify per variant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eWhere to Use the CRA D-Plate Forged D-Ring Anchor Red Powder Coating — Common Applications\u003c\/h2\u003e\n\u003cdiv class=\"fpc-sd-usecase\"\u003e\n\u003cdiv class=\"fpc-sd-usecase-card\"\u003e\n\u003ch3\u003ePermanent Rooftop Tie-Off Anchor Points\u003c\/h3\u003e\n\u003cp\u003eBuilding-owner-specified permanent anchors for ongoing HVAC service, snow removal, and exterior maintenance access.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"fpc-sd-usecase-card\"\u003e\n\u003ch3\u003eHorizontal Lifeline (HLL) End Terminations\u003c\/h3\u003e\n\u003cp\u003eEnd anchors and intermediate supports for engineered HLL runs along parapets, ridges, and across large commercial roofs.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"fpc-sd-usecase-card\"\u003e\n\u003ch3\u003eBig-Box Stores, Warehouses \u0026amp; Industrial Facilities\u003c\/h3\u003e\n\u003cp\u003eSpecified in fall protection plans for large commercial roof assemblies where multiple workers will access the roof over the life of the building.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"fpc-sd-usecase-card\"\u003e\n\u003ch3\u003eSchools, Institutional \u0026amp; Government Buildings\u003c\/h3\u003e\n\u003cp\u003ePermanent rooftop anchors meeting OSHA \/ CSA fall protection requirements for institutional facility maintenance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eWhat the CRA D-Plate Forged D-Ring Anchor Red Powder Coating Works With — Compatible Lifelines, SRLs \u0026amp; Harnesses\u003c\/h2\u003e\n\u003cdiv class=\"fpc-sd-compat\"\u003e\n\u003cp\u003e\u003cstrong\u003eHLL system integration:\u003c\/strong\u003e CRA Pass-Thru and 4-Way tops are designed to terminate or intermediate-support the Super Anchor \u003ca href=\"\/collections\/lifelines\"\u003ehorizontal lifeline systems\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp style=\"margin-bottom:0\"\u003e\u003cstrong\u003eBacker plate:\u003c\/strong\u003e required — CRA mounts through the deck and requires a 16×16″ backer plate underneath to distribute load. Order the matching backer plate with the CRA or specify your kit configuration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eHow to Install the CRA D-Plate Forged D-Ring Anchor Red Powder Coating — Installation Notes\u003c\/h2\u003e\n\u003cul class=\"fpc-sd-features\"\u003e\n\u003cli\u003eMatch riser height to insulation depth so the anchor top sits at the finished roof surface.\u003c\/li\u003e\n\u003cli\u003e16×16″ backer plate is required — CRA mounts through the deck with structural load distribution underneath.\u003c\/li\u003e\n\u003cli\u003eEngineering review by a qualified person is required for permanent commercial installations.\u003c\/li\u003e\n\u003cli\u003eInspect annually per the manufacturer’s schedule and your facility’s fall protection plan.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCRA D-Plate Forged D-Ring Anchor Red Powder Coating FAQ — Installation, Certification \u0026amp; Compatibility\u003c\/h2\u003e\n\u003cdiv class=\"fpc-sd-faq\"\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat is a CRA roof anchor?\u003c\/summary\u003e\u003cp\u003eCRA stands for Commercial Roof Anchor — Super Anchor Safety’s engineered tie-off system for commercial flat-roof and low-slope applications. CRA anchors are specified by structural engineers on big-box retail, warehouses, industrial facilities, and institutional buildings. Available in 5 heights (5\/8\/12\/18\/24″) and 4 top configurations (4-Way, Pass-Thru, W-Loop, D-Plate).\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eHow do I choose the right CRA anchor height?\u003c\/summary\u003e\u003cp\u003eMatch riser height to your roof insulation depth so the anchor top sits flush with the finished roof surface. 5″ for thin insulation assemblies; 8–12″ for typical commercial roofing; 18–24″ for deep insulation, ballasted, or tapered systems. The anchor top must reach the finished surface for proper load path.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eCRA 4-Way Loop Top vs Pass-Thru vs W-Loop vs D-Plate — which top do I need?\u003c\/summary\u003e\u003cp\u003e4-Way Loop Top: 4 independent tie-offs from one anchor (multi-worker or guy-down). Pass-Thru: cable HLL termination where the cable runs continuously through the top. W-Loop: single-direction tie-off (lower cost). D-Plate: single-point D-ring anchor. Choose based on whether you need one anchor or an HLL endpoint.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eDo CRA anchors require a backer plate?\u003c\/summary\u003e\u003cp\u003eYes. The CRA mounts through the structural deck and requires a 16×16″ backer plate underneath to distribute fall arrest load across the deck. Many CRA complete kits include the backer plate; standalone CRA tops require the backer ordered separately (1084-BPG \/ 1085-BPG series).\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eHDG vs 304 stainless vs 316 stainless — which CRA finish should I specify?\u003c\/summary\u003e\u003cp\u003eHDG (hot-dip galvanized) is the standard commercial finish, suitable for most Canadian climates. 304sst for industrial and coastal environments. 316sst for food-processing, chemical, marine, and aggressive corrosion environments. Spec finish to match the roof environment and the building owner’s maintenance horizon.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eAre CRA anchors CSA approved?\u003c\/summary\u003e\u003cp\u003eVariant-specific. CRA anchors meet OSHA 1926.502 and ANSI Z359 standards. CSA Z259 certification varies by configuration — verify the certification stamped on the anchor and on the product page. Engineered HLL configurations are reviewed per CSA Z259.16 by a qualified person.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eDo I need a Professional Engineer to install commercial CRA anchors?\u003c\/summary\u003e\u003cp\u003eFor permanent commercial CRA installations and any HLL configurations, yes — a qualified person (typically a PE in Canada) must review the fall protection plan, anchor placement, fall clearance, and deck load capacity. Super Anchor provides engineering data packages to support PE review.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eCan CRA anchors be used as horizontal lifeline terminations?\u003c\/summary\u003e\u003cp\u003eYes — CRA Pass-Thru and 4-Way Loop Top tops are engineered specifically to terminate or intermediate-support horizontal lifelines. The Super Anchor HLL system pairs with CRA anchors as line endpoints. This is the standard commercial rooftop HLL architecture in Canada.\u003c\/p\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n\u003ch2\u003eRelated Fall Protection Categories \u0026amp; Compatible Products\u003c\/h2\u003e\n\u003cdiv class=\"fpc-sd-compat\"\u003e\n\u003cp\u003e\u003cstrong\u003eBrowse related categories:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/pages\/roof-anchors-canada\"\u003eRoof Anchors Canada\u003c\/a\u003e — complete roof anchor selection guide\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/standing-seam-roof-anchors\"\u003eStanding Seam Roof Anchors\u003c\/a\u003e — non-penetrating metal roof anchors\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/shingle-roof-anchors-canada\"\u003eShingle Roof Anchors\u003c\/a\u003e — residential wood-framed roof anchors\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/harness-page\"\u003eFall Protection Harnesses\u003c\/a\u003e — CSA-certified full body harnesses\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/lifelines\"\u003eLifelines\u003c\/a\u003e — vertical and horizontal lifelines\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/srd\"\u003eSelf-Retracting Devices (SRDs \/ SRLs)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/lanyards\"\u003eLanyards \u0026amp; Shock Absorbers\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/roofing-kits\"\u003eRoofing \u0026amp; Fall Protection Kits\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"fpc-sd-ship\"\u003e\n\u003cspan class=\"fpc-sd-ship-badge\"\u003eShips Canada-Wide\u003c\/span\u003e\u003cspan\u003eIn stock and ready to ship from our Paris, Ontario warehouse. Questions on fit, certification, or kit pairing? Call \u003cstrong\u003e437-475-2066\u003c\/strong\u003e or email \u003cstrong\u003eSupport@fallprotectioncanada.com\u003c\/strong\u003e.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"Product\", \"name\": \"CRA D-Plate Forged D-Ring Anchor Red Powder Coating\", \"sku\": \"1038\", \"brand\": {\"@type\": \"Brand\", \"name\": \"Super Anchor Safety\"}, \"category\": \"Commercial Roof Anchor\", \"description\": \"Super Anchor CRA Commercial Roof Anchor \u0026mdash; (variant) riser. 5,000 lb rated. Engineered for commercial flat roofs and HLL terminations. Ships Canada-wide.\", \"countryOfOrigin\": \"US\", \"offers\": {\"@type\": \"Offer\", \"availability\": \"https:\/\/schema.org\/InStock\", \"priceCurrency\": \"CAD\", \"seller\": {\"@type\": \"Organization\", \"name\": \"Fall Protection Canada\", \"telephone\": \"+1-437-475-2066\", \"email\": \"Support@fallprotectioncanada.com\", \"address\": {\"@type\": \"PostalAddress\", \"streetAddress\": \"51 Folsetter Dr\", \"addressLocality\": \"Paris\", \"addressRegion\": \"ON\", \"addressCountry\": \"CA\"}}}, \"additionalProperty\": [{\"@type\": \"PropertyValue\", \"name\": \"Manufacturer\", \"value\": \"Super Anchor Safety\"}, {\"@type\": \"PropertyValue\", \"name\": \"Product Type\", \"value\": \"Commercial Roof Anchor (CRA Series)\"}, {\"@type\": \"PropertyValue\", \"name\": \"Riser Height\", \"value\": \"(variant)\"}, {\"@type\": \"PropertyValue\", \"name\": \"Top Configuration\", \"value\": \"Variant-specific (4-Way \/ Pass-Thru \/ W-Loop \/ D-Plate)\"}, {\"@type\": \"PropertyValue\", \"name\": \"Finishes\", \"value\": \"HDG (Hot-Dip Galvanized) \/ 304sst \/ 316sst\"}, {\"@type\": \"PropertyValue\", \"name\": \"Backer Plate\", \"value\": \"16\u0026times;16\u0026times;3\/8\u0026Prime; or 16\u0026times;16\u0026times;5\/8\u0026Prime; (variant)\"}]}\u003c\/script\u003e\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is a CRA roof anchor?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"CRA stands for Commercial Roof Anchor \u0026mdash; Super Anchor Safety\u0026rsquo;s engineered tie-off system for commercial flat-roof and low-slope applications. CRA anchors are specified by structural engineers on big-box retail, warehouses, industrial facilities, and institutional buildings. Available in 5 heights (5\/8\/12\/18\/24\u0026Prime;) and 4 top configurations (4-Way, Pass-Thru, W-Loop, D-Plate).\"}}, {\"@type\": \"Question\", \"name\": \"How do I choose the right CRA anchor height?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Match riser height to your roof insulation depth so the anchor top sits flush with the finished roof surface. 5\u0026Prime; for thin insulation assemblies; 8\u0026ndash;12\u0026Prime; for typical commercial roofing; 18\u0026ndash;24\u0026Prime; for deep insulation, ballasted, or tapered systems. The anchor top must reach the finished surface for proper load path.\"}}, {\"@type\": \"Question\", \"name\": \"CRA 4-Way Loop Top vs Pass-Thru vs W-Loop vs D-Plate \u0026mdash; which top do I need?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"4-Way Loop Top: 4 independent tie-offs from one anchor (multi-worker or guy-down). Pass-Thru: cable HLL termination where the cable runs continuously through the top. W-Loop: single-direction tie-off (lower cost). D-Plate: single-point D-ring anchor. Choose based on whether you need one anchor or an HLL endpoint.\"}}, {\"@type\": \"Question\", \"name\": \"Do CRA anchors require a backer plate?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. The CRA mounts through the structural deck and requires a 16\u0026times;16\u0026Prime; backer plate underneath to distribute fall arrest load across the deck. Many CRA complete kits include the backer plate; standalone CRA tops require the backer ordered separately (1084-BPG \/ 1085-BPG series).\"}}, {\"@type\": \"Question\", \"name\": \"HDG vs 304 stainless vs 316 stainless \u0026mdash; which CRA finish should I specify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"HDG (hot-dip galvanized) is the standard commercial finish, suitable for most Canadian climates. 304sst for industrial and coastal environments. 316sst for food-processing, chemical, marine, and aggressive corrosion environments. Spec finish to match the roof environment and the building owner\u0026rsquo;s maintenance horizon.\"}}, {\"@type\": \"Question\", \"name\": \"Are CRA anchors CSA approved?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Variant-specific. CRA anchors meet OSHA 1926.502 and ANSI Z359 standards. CSA Z259 certification varies by configuration \u0026mdash; verify the certification stamped on the anchor and on the product page. Engineered HLL configurations are reviewed per CSA Z259.16 by a qualified person.\"}}, {\"@type\": \"Question\", \"name\": \"Do I need a Professional Engineer to install commercial CRA anchors?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"For permanent commercial CRA installations and any HLL configurations, yes \u0026mdash; a qualified person (typically a PE in Canada) must review the fall protection plan, anchor placement, fall clearance, and deck load capacity. Super Anchor provides engineering data packages to support PE review.\"}}, {\"@type\": \"Question\", \"name\": \"Can CRA anchors be used as horizontal lifeline terminations?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes \u0026mdash; CRA Pass-Thru and 4-Way Loop Top tops are engineered specifically to terminate or intermediate-support horizontal lifelines. The Super Anchor HLL system pairs with CRA anchors as line endpoints. This is the standard commercial rooftop HLL architecture in Canada.\"}}]}\u003c\/script\u003e","brand":"Super Anchor Safety","offers":[{"title":"1038","offer_id":51383235739943,"sku":"1038","price":149.0,"currency_code":"CAD","in_stock":false},{"title":"1038-S","offer_id":51383235772711,"sku":"1038-S","price":189.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/7249\/7447\/files\/1038.jpg?v=1778525671","url":"https:\/\/fallprotectioncanada.com\/products\/cra-d-plate-forged-d-ring-anchor-red-powder-coating","provider":"Fall Protection Canada","version":"1.0","type":"link"}