Super Anchor 1031-4G CRA-4 5" 4-Way Anchor Post | Canada
Super Anchor 1031-4G CRA-4 5" 4-Way Anchor Post documents
Super Anchor Safety's own documents.
Super Anchor 1031-4G CRA-4 5" 4-Way Anchor Post | Canada
The Super Anchor 1031-4G is a 5 inch CRA-4 4-way anchor post, the riser that anchors horizontal lifeline intersections when fitted with the No. 1054 4-Way Top Fixture, sold separately. The foam filled, hot dip galvanized 3.0 inch Schedule 40 riser stands on a 4-hole 6x6x3/8 inch base plate, and the anchor is third-party certified with a 5,000 lb ultimate strength. What is included: the riser post with base plate only; the No. 1054 top fixture is not included. The bare riser tube accepts the No. 1054 4-Way Top Fixture, which is required and sold separately, secured with a 1/2 x 4-1/2 inch stainless attachment bolt and 3 set screws. The fixture accepts up to 4 HLL run attachments for T, 90 degree, 45 degree, and 4-way intersections, plus single person loop top tie-off. Because 4-way anchors serve horizontal lifelines, they must be bolted, field welded, or concrete embedded, never screw attached. Compliant with ANSI Z359.18-17 and OSHA 1926.502, with CSA Z259.15:22 conformity per the 01-2023 manual.
Typical Applications for the Super Anchor 1031-4G
- HLL Intersections — T, 90 degree, 45 degree, and 4-way run junctions.
- Multi-Run Roof Systems — Ties several lifeline runs to one anchor point.
- Low Profile Intersections — 5 inch riser hugs the deck at membrane level.
- Single Person Tie-Off — Loop top PPE anchorage via the 1054 fixture.
- Concrete Decks — Wedge bolt, epoxy, or poured-in-place installations.
- Structural Steel — Bolt attached or field welded to steel members.
- Metal Decking — Bolted through Type B decking with backer plates.
- Perimeter Systems — Corner posts where perimeter runs change direction.
Super Anchor 1031-4G Specifications
| Specification | Detail |
|---|---|
| SKU | 1031-4G |
| Model | 1031-4G, CRA-4 5 inch |
| Top Fixture | No. 1054 4-Way Top Fixture required, sold separately; attaches with a 1/2 x 4-1/2 inch stainless hex bolt with seal washers both ends plus 3 set screws |
| Riser | 5 inch height, 3.0 inch O.D. Schedule 40 [6mm], polyurethane foam filled, ASTM 123 hot dip galvanized |
| Base Plate | 6 x 6 x 3/8 inch with 4 bolt holes |
| Ultimate Strength | 5,000 lb minimum in any direction the load is applied |
| Proof Load | Maximum 2,500 lb on site |
| Design Load | 1,250 lb at a 4 to 1 design factor |
| HLL Capacity | Up to 4 HLL run attachments at the 4-way top; 2 workers fall arrest or 4 workers fall restraint per run at 310 lb per user |
| Run Length | Typically 120 ft; up to 130 ft with third party engineering; anchors 20 to 30 ft on center |
| Attachment | Bolted, field welded, or concrete embedded only; never screw attached |
| Temperature Rating | -30 to +130 degrees F |
| Product Weight | 7 lb |
| Compliance | ANSI Z359.18-17 Type A/T; OSHA 1926.502 and 1910.140; CSA Z259.15:22 Type A/T; Intertek lab reports; third-party engineering by DH Glabe and Associates |
| UPC | 786158103168 |
| Brand | Super Anchor Safety |
Super Anchor 1031-4G Standards — ANSI, OSHA & CSA Use in Canada
For Canadian worksites, confirm the CSA Z259 documentation your province requires before use — Super Anchor's own documents are linked at the top of this page.
Buy the Super Anchor 1031-4G — Shipped Across Canada
Questions about fit, compatibility or a full system? Contact Fall Protection Canada before you order.