The Super Anchor 1031-W is a 5 inch CRA anchor post with a No. 1090 cast steel loop top rated at 10,000 lb tensile strength on a foam filled, hot dip galvanized Schedule 40 riser. The 6x6x3/8 inch 4-hole base plate bolts to structure with the included 4 stainless 1/2 x 1-3/4 inch bolts with lock nuts and washers, and the anchor is third-party certified with a 5,000 lb ultimate strength in any load direction. Use it as a single person tie-off point, a window washing tie-back, or an end anchor in CRA horizontal lifeline systems up to 240 ft. The 4-hole base also bolts to the corner holes of the 1207 standing seam plate for loop top anchorage on metal roofs. Compliant with ANSI Z359.18-17 and OSHA 1926.502, with CSA Z259.15:22 conformity per the 01-2023 manual.
Typical Applications for the Super Anchor 1031-W
- Tie-Off Anchor — Single person PPE anchor on commercial roofs and structures.
- HLL End Anchor — End anchorage for CRA horizontal lifelines up to 240 ft.
- Standing Seam Roofs — Bolts to the 1207 plate corner holes for metal roof anchorage.
- Window Washing — Tie-back and fall arrest anchorage per ANSI/IWCA 1-14.1.
- Concrete Decks — Wedge bolt, epoxy, or poured-in-place installations.
- Structural Steel — Bolt attached or field welded to steel members.
- Wood Framing — Bolted with backer plates per the manual figures.
- Metal Decking — Attached to Type B decking per fastener specifications.
Super Anchor 1031-W Specifications
| Specification | Detail |
|---|---|
| SKU | 1031-W |
| Loop Top | No. 1090 Q235 cast steel, 1-3/8 inch inside diameter, 10,000 lb minimum tensile strength |
| Riser | 5 inch height, 3.0 inch O.D. Schedule 40, polyurethane foam filled, ASTM 123 hot dip galvanized |
| Base Plate | 6 x 6 x 3/8 inch with 4 bolt holes; includes 4 stainless 1/2 x 1-3/4 inch bolts with lock nuts and washers |
| Ultimate Strength | 5,000 lb minimum in any direction the load is applied to the loop top |
| Proof Load | Maximum 2,500 lb on site; do not proof load screw attached anchors |
| Design Load | 1,250 lb at a 4 to 1 design factor |
| User Capacity | 1 person at 340 lb maximum including tools and equipment; 6 ft maximum free fall |
| Anchor Spacing | 20 to 30 ft on center for single person and HLL anchors; 12 ft or less for window washing |
| Temperature Rating | -30 to +130 degrees F |
| Structural Requirement | 5,000 lb or 2 times the intended fall protection load per OSHA 1910.140 |
| Compliance | ANSI Z359.18-17 Type A/T; OSHA 1926.502 and 1910.140; CSA Z259.15:22 Type A/T; ANSI/IWCA 1-14.1 window washing; Intertek lab reports; third-party engineering by DH Glabe and Associates |
| Brand | Super Anchor Safety |
Super Anchor 1031-W Standards — ANSI, OSHA & CSA Use in Canada
For Canadian worksites, confirm the CSA Z259 documentation your province requires before use — Super Anchor's own documents are linked at the top of this page.
Buy the Super Anchor 1031-W — Shipped Across Canada
Questions about fit, compatibility or a full system? Contact Fall Protection Canada before you order.