Frontline RO Commercial Roof Anchor – 22.2 kN Fall Protection Tie-Off Point (Hot Dip Galvanized)
Frontline RO Commercial Roof Anchor. A multi-purpose commercial roof anchor for fall arrest, fall restraint, work positioning and rescue, indoors or outdoors. It installs in concrete, metal or wood, comes with fasteners, and is made of ASTM-rated steel with an ASTM-rated hot-dip galvanized finish, welded by AWS-certified welders. Use it with SRLs, shock-absorbing lanyards and vertical or horizontal lifelines. 12 in or 18 in heights; 5,000 lbf / 22 kN minimum breaking strength; 310 lb maximum user capacity.
Frontline RO commercial roof anchor key features
- For fall arrest, fall restraint, work positioning and rescue
- Installs in concrete, metal and wood substrates
- Indoor and outdoor use
- ASTM-rated steel for high strength
- ASTM-rated hot-dip galvanized finish for all weather
- Welded by AWS-certified welders using certified processes
- Fasteners included, ready to install
- Works with SRLs, shock-absorbing lanyards and vertical and horizontal lifelines
Frontline RO roof anchor specifications and heights
| Manufacturer | Frontline Fall Protection |
|---|---|
| Model | RO (12 in or 18 in) |
| Material | ASTM-rated steel |
| Finish | ASTM-rated hot-dip galvanized |
| Welding | AWS-certified welders and processes |
| Substrates | Concrete, metal, wood |
| Fasteners | Included |
| Minimum breaking strength | 5,000 lbf / 22 kN |
| Maximum user capacity | 310 lb |
| Standards | Meets or exceeds ANSI Z359.18, ANSI A10.32, OSHA 1926 and OSHA 1910 |
| Testing | Independent third-party lab accredited to ISO/IEC 17025 |
| Region | Stocked by Fall Protection Canada in Paris, Ontario · ships Canada-wide |
Where crews use the Frontline RO commercial roof anchor
Commercial roofs
A fixed tie-off point on concrete, steel or wood roof structures.
Rooftop maintenance
Permanent anchors for HVAC, solar and service crews.
Lifeline end points
Anchor vertical or horizontal lifelines as well as SRLs and lanyards.
Is the Frontline RO roof anchor CSA certified? Compliance in Canada
Is the Frontline RO roof anchor CSA certified?
No. Frontline states it meets or exceeds ANSI Z359.18, ANSI A10.32, OSHA 1926 and OSHA 1910. For CSA-marked anchors, see our Safety Direct range.
What can the RO anchor be installed in?
Concrete, metal or wood, with the fasteners included. Have a qualified person confirm the structure and follow Frontline's instructions.
Which height should I choose, 12 in or 18 in?
Pick the height that clears your roofing, insulation and membrane build-up.
What is the user capacity?
310 lb maximum, with a 5,000 lbf / 22 kN minimum breaking strength.
Pair the Frontline RO anchor with roof fall protection gear
Add a full body harness and an SRL or shock-absorbing lanyard, or run a lifeline between anchors. Questions on fit or quantities? Contact Fall Protection Canada.