Guardian 00484 Bull Ring Roof Anchor, 2-Pack | Canada
Guardian 00484 Bull Ring reusable roof anchor, 2-pack. A Type A anchorage connector in galvanized steel with a pivoting bull ring that loads from both sides. Wood substrates only, reusable with new fasteners each install, compatible with horizontal lifelines and rated for personal fall arrest, restraint and work positioning. 2.25 lb each, fasteners included.
Guardian 00484 Bull Ring roof anchor key features
- Pivoting bull ring that can be loaded from both sides
- Galvanized steel, Type A anchorage connector
- Reusable: new fasteners for each new installation
- Compatible with horizontal lifelines (installed perpendicular to the long side)
- Hole pattern takes 6 x 16d nails or 5 x 1/4 x 3 in lag screws; fasteners included
- Rated for personal fall arrest, restraint and work positioning
- Minimum service temperature -30°F
Guardian 00484 Bull Ring roof anchor specifications
| Manufacturer | Guardian Fall Protection |
|---|---|
| Model | 00484 Bull Ring Anchor, galvanized (sold here as a 2-pack) |
| Type | Type A anchorage connector |
| Weight | 2.25 lb each |
| Material | Galvanized steel |
| Minimum breaking strength | 5,000 lb |
| Worker capacity | 130-420 lb, 1 user |
| Roof pitch | 0/12 to sheer |
| Substrate | Wood only, 3.5 in total combined thickness |
| Fasteners | 5 x 1/4 x 3 in steel hex head lag screws or 6 x 16d nails (nails meet OSHA only, not ANSI) |
| Inspection | Before each use; Competent Person at least every 6 months |
| Standards | OSHA 1926 Subpart M, OSHA 1910, ANSI Z359.18-2017, ANSI A10.32-2012 |
Where the 00484 Bull Ring roof anchor earns its keep
Residential roofing
Reusable tie-off point on wood roof decks.
Horizontal lifelines
Works as an HLL anchor, installed perpendicular to the long side.
Work positioning
Rated for work positioning with side D-rings.
Two-ended coverage
A 2-pack for both ends of the roof or two work zones.
00484 Bull Ring roof anchor questions and CSA status
Is the Guardian 00484 Bull Ring roof anchor CSA certified?
No. Guardian lists OSHA 1926 Subpart M, OSHA 1910, ANSI Z359.18-2017 and ANSI A10.32-2012, not CSA Z259. For CSA-marked anchors see our Safety Direct range.
Can the Guardian Bull Ring anchor be reused?
Yes. Guardian lists it as reusable; use new fasteners for each new installation and check it is not damaged or warped first.
Nails or lag screws on the Guardian 00484?
Either 6 x 16d nails or 5 x 1/4 x 3 in lag screws. Guardian notes nail installation meets OSHA only, not ANSI.
What roofs suit the Guardian 00484 Bull Ring?
Wood substrates only, 3.5 in total combined thickness, roof pitch 0/12 to sheer.
Pair the 00484 Bull Ring roof anchor with a full system
Pair the Bull Ring with a full-body harness and a rope lifeline, SRL or horizontal lifeline for a complete fall protection system.