MSA Workman 10102686 Reusable Roof Anchor, Galvanized | Canada
MSA Workman 10102686 reusable roof anchor, galvanized. MSA's reusable hinged roof anchor gives a personal fall arrest anchor point on wooden roofs for maintenance, repair and new construction. Galvanized steel, offset centre holes, fits roofs up to 12/12 pitch and ships with 12 mounting screws. 2.16 lb.
MSA Workman 10102686 reusable roof anchor key features
- Offset centre holes reduce the chance of splitting the truss during installation
- Installs with screws or nails; 12 mounting screws included
- Use off the roof peak in a flat position without compromising strength
- Fits any wooden roof up to 12/12 pitch
- Reusable, hinged design
- One user, 400 lb maximum capacity
- Labels and instructions in English and Spanish
MSA Workman 10102686 roof anchor specifications
| Manufacturer | MSA Safety |
|---|---|
| Model / part no. | 10102686 Workman reusable roof anchor, hinged |
| Material | Galvanized steel |
| Dimensions | 18.4 x 3.0 x 2.9 in (46.7 x 7.6 x 7.4 cm) |
| Net weight | 2.16 lb (0.98 kg) |
| Capacity | One user, 400 lb (181 kg) including clothing and tools |
| Max arresting force | 1,800 lbf (8 kN) in a personal fall arrest system |
| Roof | Wooden roofs up to 12/12 pitch |
| Fasteners | 12 mounting screws included; nails also permitted |
| Standards with screws | ANSI Z359.1-2007, ANSI A10.32-2004, OSHA 1926.502 |
| Standards with nails | ANSI A10.32-2004, OSHA 1926.502 |
Where the MSA Workman 10102686 roof anchor works
Re-roofing
Reusable anchor that moves job to job.
New construction
Anchor point while the roof goes on.
Maintenance and repair
Quick anchor for short roof jobs.
Off-peak placement
Works flat, away from the peak.
MSA Workman 10102686 anchor questions and CSA status
Is the MSA Workman 10102686 roof anchor CSA certified?
No. MSA lists ANSI Z359.1-2007, ANSI A10.32-2004 and OSHA 1926.502, not CSA Z259. For CSA-marked roof anchors see our Safety Direct range.
Should I install the MSA Workman 10102686 with screws or nails?
Either is permitted, but MSA lists ANSI Z359.1-2007 only for screw installation. The 12 mounting screws are included.
What roof pitch does the MSA Workman 10102686 fit?
Any wooden roof up to 12/12 pitch.
How many workers can use one MSA Workman 10102686?
One worker, up to 400 lb including clothing, tools and equipment.
Pair the MSA Workman 10102686 anchor with a full system
Pair the Workman 10102686 with a full-body harness and a shock-absorbing lanyard or SRL for a complete roof fall arrest system.