Super Anchor 1207 Standing Seam Anchor Kit | CSA Canada
The Super Anchor 1207 Standing Seam Plate Kit is a non-penetrating fall protection anchor engineered for standing seam metal roofs. The aluminum plate locks onto the seams with four RCT clamps — no holes drilled, no flashing required — and is third-party tested to 5,000 lb (22.2 kN) in the specified load direction. Compatible with roughly 95% of modern standing seam profiles in widths from 12″ to 24″.
Why Metal Roofers & Solar Installers Choose the Super Anchor 1207 Standing Seam Plate Kit
- Zero roof penetrations — preserves the manufacturer roof warranty and waterproof envelope
- Lightweight aluminum plate stands up to coastal and high-humidity Canadian climates without corroding
- Four RCT seam clamps with 3× 3/8″ stainless steel hex screws per clamp grip the seam profile — not the panel face
- 5,000 lb minimum static strength — rated for personal fall arrest, restraint, and work positioning
- Includes a Super Anchor 1028 swivel D-ring — rotates 360° so the lanyard always pays out clean
- Three plate sizes (1207-12×18, 1207-14×22, 1207-18×24) cover wide-profile T-seams, mechanical-lock seams, snap-lock seams and bulb seams
- Removable — relocate between jobs, reuse across roof sections, or leave permanently installed
- Made in USA by Super Anchor Safety, certified under ANSI Z359 & CSA Z259.15
Super Anchor 1207 Standing Seam Plate Kit Specifications & Load Ratings
| Manufacturer | Super Anchor Safety (USA) |
|---|---|
| Product Type | Non-penetrating standing seam roof anchor — kit |
| Substrate | Standing seam metal roof panel (steel, aluminum, copper, zinc) |
| Mounting Method | Non-penetrating — clamps onto the vertical seam, no panel piercing |
| Plate Material | Aluminum, lightweight high-strength alloy |
| Clamp Material | Stainless steel RCT (Roof Clamp T-profile) clamps |
| D-Ring | Super Anchor 1028 swivel D-ring — 360° rotation, 5,000 lb rated |
| Rated Capacity | 5,000 lb (22.2 kN) minimum static strength in specified load direction |
| User Capacity | 1 worker per anchor (per OSHA 1926.502 & CSA Z259.15) |
| Plate Sizes Available | 1207-12×18 · 1207-14×22 · 1207-18×24 |
| Seam Width Range | 12″ to 24″ (fits ~95% of standing seam profiles) |
| Fasteners per Clamp | 3× 3/8″ stainless steel hex screws (12 screws total per anchor) |
| Kit Contents | (1) 1207 aluminum plate · (4) RCT seam clamps · (1) 1028 swivel D-ring · mounting hardware |
| Certifications | ANSI Z359.18 · CSA Z259.15 · OSHA 1926.502 |
| Country of Origin | USA |
Where to Use the Super Anchor 1207 Standing Seam Plate Kit — Common Applications
Commercial Standing Seam Roof Maintenance
Tie off for roof inspections, gutter service, and panel repair on warehouses, big-box retail, and industrial facilities — without voiding the metal-roof warranty.
Rooftop Solar Array Installation
Crew safety during PV racking, panel mounting, and electrical run-outs on standing seam commercial and agricultural roofs.
HVAC & Mechanical Service Access
Permanent anchor point near rooftop units for ongoing HVAC service, chiller maintenance, and exhaust-fan replacement.
Snow & Ice Removal on Metal Roofs
Single-worker tie-off for steep-slope standing seam snow shedding in Canadian winter conditions — paired with a rope grab and vertical lifeline.
Photovoltaic Inspection & O&M
Recurring solar O&M crews leave the 1207 installed across the array’s service life.
Re-Roofing Over Existing Metal
Temporary tie-off during metal-over-metal re-roof projects where the existing roof must stay watertight.
What the Super Anchor 1207 Standing Seam Plate Kit Works With — Compatible Lifelines, SRLs & Harnesses
Pair the 1207 anchor with a Super Anchor lifeline + rope grab + harness. The 1028 swivel D-ring accepts any CSA/ANSI-rated double-locking snaphook or carabiner — common pairings include the Maxima 25ft Lifeline, SuperGrab Rope Grab, SideWinder SRL, and the Deluxe Full Body Harness.
For permanent horizontal lifeline (HLL) applications: two 1207 plates serve as end anchors for a Super Anchor 1050-G or 304sst HLL rope kit, creating a continuous tie-off path along the roof line.
Need a complete kit? Browse our Fall Protection Kits or contact us and we’ll spec the lifeline and harness to your jobsite.
How to Install the Super Anchor 1207 Standing Seam Plate Kit — Installation Notes
- Confirm seam profile and width — match the plate size (12″, 14″, or 18″) to the panel rib spacing on your roof. The RCT clamp fits T-profile, mechanical-lock, snap-lock and bulb seam types.
- Position the aluminum plate over four standing seams so all four RCT clamp locations sit directly on a seam — never on the flat panel face.
- Slip each RCT clamp over the seam, align with the plate mounting hole, and seat with the supplied hardware.
- Drive three 3/8″ stainless steel hex screws per clamp into the clamp jaw (not through the panel). Torque per the Super Anchor SSCA manual.
- Install the 1028 swivel D-ring into the plate’s center boss — verify the D-ring rotates 360° freely.
- Inspect before every use: clamp jaw integrity, seam deformation under the clamp, fastener torque, plate flatness, D-ring wear.
- After a fall-arrest event, remove the anchor from service immediately and replace per the manufacturer’s instructions.
- For two-anchor HLL applications, follow the Super Anchor SSCA manual for span limits, sag allowance, and end-load engineering.
Super Anchor 1207 Standing Seam Plate Kit FAQ — Installation, Certification & Compatibility
What is the Super Anchor 1207 standing seam plate kit?
The 1207 is a non-penetrating fall protection anchor for standing seam metal roofs, manufactured by Super Anchor Safety. The kit includes an aluminum plate, four RCT seam clamps, and a 1028 swivel D-ring. The plate locks onto four standing seams via the clamps — no holes are drilled into the roof panel. Third-party tested to 5,000 lb minimum static strength under ANSI Z359, CSA Z259.15, and OSHA 1926.502.
Does the 1207 anchor penetrate the metal roof?
No. The 1207 is a fully non-penetrating anchor. The four RCT clamps grip the vertical seam of each standing seam panel, and the stainless steel hex screws engage the clamp jaw — not the panel face. The metal roof manufacturer warranty and waterproof envelope are preserved.
What load rating does the 1207 plate kit carry?
Each 1207 plate is third-party certified to a 5,000 lb (22.2 kN) minimum static load in the specified direction. This is a single-user fall arrest, restraint, and work positioning rating under ANSI Z359.18 and CSA Z259.15. For multi-worker scenarios, install one anchor per worker or engineer an HLL system.
Which standing seam profiles does the 1207 fit?
The RCT clamp system is compatible with roughly 95% of modern standing seam profiles, including T-profile, mechanical-lock, snap-lock, double-lock, and bulb seam panels. The three plate sizes (12×18, 14×22, 18×24) cover seam widths from 12″ to 24″. If you’re unsure of your panel profile, send us a cross-section image of the seam and we’ll confirm fit.
How many workers can tie off to one 1207 anchor?
One worker per anchor under OSHA 1926.502 and CSA Z259.15. The 5,000 lb rating is a single-user fall arrest capacity. For multi-worker crews, install one 1207 per worker or build a horizontal lifeline (HLL) between two 1207 end anchors per the Super Anchor SSCA manual.
Is the 1207 CSA approved for use in Canada?
Yes. The Super Anchor 1207 is third-party certified to CSA Z259.15 and ANSI Z359.18. Canadian provincial OHS codes (Ontario O. Reg. 213/91, Alberta OHS Code Part 9, BC OHS Reg. 11.71, Quebec S-2.1) require CSA-certified anchors for fall protection on construction and industrial sites — the 1207 meets that requirement.
Can the 1207 plate kit be used as an HLL end anchor?
Yes. Two 1207 plate anchors can serve as the end terminations for a Super Anchor horizontal lifeline (HLL) rope kit, such as the 1050-G galvanized or 304sst stainless steel HLL systems. Refer to the SSCA installation manual for permissible span lengths, sag allowance, and end-load engineering.
Is the 1207 anchor permanent or removable?
Both. The 1207 can be left permanently installed for ongoing rooftop service (solar O&M, HVAC, gutter cleaning) or removed and relocated for one-off jobs. Because the kit is non-penetrating, removal leaves no holes, no sealant residue, and no warranty impact.
What is included in the 1207 standing seam plate kit?
One Super Anchor 1207 aluminum plate, four RCT non-penetrating seam clamps, one 1028 swivel D-ring, and all required mounting hardware (stainless 3/8″ hex screws — three per clamp, twelve total).
Where can I buy the Super Anchor 1207 in Canada?
This 1207 kit ships Canada-wide with CAD pricing — no cross-border duty, no brokerage surprises. Quantity discounts available for fleet, solar EPC, and commercial roofing buyers; contact us for a project quote.